For a lot of families this is the actual reason to build instead of buy.
The existing housing stock in this valley was not built for a wheelchair, a walker, or a parent who will need a bathroom they can get into without help. Remodeling your way there is possible and it is almost always a compromise. Starting from a blank site is not.
So here is the thing to understand first: nothing requires any of this, and no inspector will catch a mistake.
No accessibility law applies to the house you are building
This surprises people, and it is worth being precise about, because a lot of what gets written on this subject implies otherwise.
The ADA does not cover your home. The ADA National Network states it plainly: "The ADA does not cover strictly residential private apartments and homes." The one exception is a portion of a residence used as a place of public accommodation, such as a doctor's office or a day care.
The Fair Housing Act does not cover it either. HUD's overview of the design and construction requirements applies them to covered multifamily dwellings: all units in buildings of four or more with an elevator, and all ground-floor units in buildings of four or more without one. Detached single-family houses, duplexes, and triplexes are not covered.
And the residential code does not require it. The IRC's accessibility section points to the IBC's Group R-3 provisions only where a structure contains four or more dwelling or sleeping units. A published reading of that section confirms detached one- and two-family dwellings are not directed there. That reading is of the 2021 edition and paraphrased, and Idaho is on the 2018 IRC, so confirm the section with your building department. The shape of the answer does not change.
Every accessibility decision in your house is therefore a design decision, made by you and your builder, enforced by nobody, and most of them cannot be added later.
Borrow the checklist anyway
The seven Fair Housing design requirements exist because multifamily builders would not do these things voluntarily. They are a tested list of what makes a dwelling usable, and nothing stops you from using it where it does not apply:
- An accessible building entrance on an accessible route
- Accessible and usable common areas
- Usable doors
- Accessible routes into and through the unit
- Light switches, outlets, thermostats and other controls in accessible locations
- Reinforced bathroom walls for later installation of grab bars
- Usable kitchens and bathrooms
Read item six again. The federal requirement for apartments is not grab bars. It is walls that can take grab bars later. That is the whole philosophy of building this way: do the structural and dimensional work now, when it is nearly free, and let the visible hardware wait until somebody needs it.
The dimensions that decide your floor plan
These numbers come from the federal standards for public buildings, so they are benchmarks for a house rather than requirements. They are also the best-tested dimensions available, and designers use them for exactly that reason.
From the Access Board's published comparison of the standards:
- Turning space. A 60 inch minimum diameter circle, or a T-shaped space within a 60 inch square with arms and base at least 36 inches wide. Floor slope no steeper than 1:48, no changes in level.
- Clear floor space for a wheelchair: 30 inches wide by 48 inches long, positioned for a forward or parallel approach.
- Reach range. 15 inches minimum low, 48 inches maximum high. Reaching over an obstruction more than 20 inches deep drops the high reach to 44 inches.
- Knee and toe clearance. Toe clearance to 9 inches high, knee clearance from 9 to 27 inches, 30 inches minimum width. This is what makes a sink approachable rather than just nearby.
- Doors need a 32 inch clear opening, which in practice means a 36 inch door. Michigan's state guidelines for zero-step construction call for 34 inches clear, a better target if you have the wall to give.
Now notice what those are. A 60 inch turning circle in a bathroom, 36 inch doors throughout, and knee clearance under a sink are not finishes. They are plan dimensions. They set room sizes, which set the footprint, which sets the price. They have to be in the drawings before anybody quotes the house, and they are the single most expensive category of change once the slab is poured.
The zero-step entry, and why it is harder here
Every accessible house needs one way in with no step. In a climate like this one, that entry is a genuine construction problem rather than a detail.
The Journal of Light Construction describes two approaches. The cheap one brings finished grade up against the band joist, and JLC is candid that "careful flashing is needed to prevent insect infestation and rot." The better one raises the foundation walls near the entry by about a foot and frames the floor so its top sits level with the top of the mudsill. That keeps soil away from wood framing and lets the house entry and the garage floor land at the same level.
The second method costs more at the foundation and it is the one we would build, because the failure mode of the first one is rot in the exact assembly you cannot inspect.
On the approach, Michigan's guidelines give workable numbers: primary walks no steeper than 1:20, cross slope no more than 1:48, at least 36 inches of clear width, and a turning space at least 5 feet in diameter at the primary door. Where grade forces a ramp, 1:12 maximum, no more than 30 inches of rise between landings, landings at least 60 inches long, and handrails both sides at 34 to 38 inches. Thresholds: half an inch maximum, three quarters for an exterior slider.
Here is the part neither source addresses, and it is the part that matters locally. Neither JLC nor Michigan deals with frost, snow or ice. This is our judgment rather than a published requirement:
- Both jurisdictions here publish a 24 inch frost depth, so a flush entry still sits on a foundation carried below frost. A stoop poured on fill is the thing that moves.
- A no-step entry has no step to shed water, so positive drainage away from the threshold is not optional, and overhead cover is doing double duty: it keeps rain off and keeps snow and ice off the one entrance that has to work.
- A 1:20 walk is shallow, and a shallow slope holds snow. Somebody clears it, which argues for a short approach under cover rather than a long elegant one out in the weather.
- Put the garage entry at the same level as the house entry. The entrance a family actually uses through a Magic Valley winter is the one from inside the garage. An accessible front door paired with a two-step mudroom is a house that is accessible in July.
That last point is the one we would argue hardest for, and it costs almost nothing if it is decided before the foundation.
Grab bars, and the number that explains the whole approach
Grab bars are the clearest example of cheap now versus expensive later.
Section 609 of the 2010 standards specifies an outside diameter of 1¼ to 2 inches, exactly 1½ inches of clearance to the wall, and mounting 33 to 36 inches above the finished floor. Then section 609.8 sets the structural requirement: allowable stresses must not be exceeded when a vertical or horizontal force of 250 pounds is applied at any point on the grab bar.
And that 250 pounds applies to the bar, its fasteners, its mounting device, and its supporting structure.
Supporting structure means blocking, which means it happens while the walls are open, not when somebody needs a bar. A grab bar screwed into drywall with anchors is not a grab bar, it is a handle that will come off the wall the first time it is used for its actual purpose. We covered blocking generally in a separate post, and bathrooms are where that argument is least theoretical.
While the walls are open is also when the bathroom gets sized. A roll-in shower is 30 inches wide by 60 inches deep minimum with a 60 inch wide entry and a half inch maximum threshold. A transfer shower is 36 by 36 clear with a seat. Both are framing and plumbing decisions made long before tile.
What is nearly free now and expensive later
No dollar figures, because we would be making them up. But the ordering is reliable.
Nearly free during construction: blocking in bathroom walls, 36 inch doors instead of 32, outlets and switches inside the reach range, a bathroom sized for a turning circle, conduit or stacked closets for a future lift, the garage and house entries at one level, a wider hallway while the walls are still lines on paper.
Expensive later: every single one of those.
The one that is effectively impossible later: the footprint. If the house is too small to hold a 60 inch turning circle in the main bathroom, no remodel fixes that without taking space from somewhere else.
Two structural notes
Single story is the default answer, and if it is not, plan the shaft. Stacked closets on both floors, framed and sized now, give you a residential elevator later without opening the structure. Without them, the second floor eventually becomes storage.
Barndominiums are quietly good at this. Naturally single-story, long clear spans, few interior bearing walls. That is the geometry that makes wide doors and generous turning space easy rather than expensive. If an accessible layout keeps colliding with bearing walls in a conventional plan, it is worth a conversation.
What to ask your builder
- Is there one entrance with no step, and is it the one from the garage?
- How is that entry built, and does grade touch wood framing anywhere?
- Does the main bathroom hold a 60 inch turning circle, drawn on the plan?
- Are interior doors 36 inch, and is that in the plan or an upgrade?
- Where is the blocking going, and is it rated for 250 pounds at any point?
- Are switches, outlets and thermostats inside a 15 to 48 inch reach range?
- If this is two stories, where does a lift go later?
- What on this list is in the base price and what is an allowance?
Question three is the one that decides whether the rest is even possible, because it is a footprint question disguised as a bathroom question.
Building for a family member in the Magic Valley?
We build custom homes, additions, ADUs, shops, remodels, and barndominiums across Twin Falls, Jerome, Kimberly, Buhl, Filer, Burley, Rupert, and unincorporated Twin Falls County.
Because no code requires any of this, it only happens if somebody draws it and somebody builds it on purpose. We will put these dimensions on the plan before the house is priced, tell you which items are nearly free now, and say plainly which ones stop being available once the foundation is in.
We are a registered Idaho contractor, RCE-65510, insured and warrantied.
Tell us about your project → or call (208) 731-1729
The ADA and Fair Housing determinations above are from the sources linked and concern whether those laws apply, not how to design for any individual's needs. Dimensional standards cited are federal standards for public buildings and state guidance from another state, offered as design benchmarks because no accessibility standard governs a detached single-family home. Two sections are cited from published code compilations rather than the publisher's own text, and the IRC reading cited is of a different edition than the one Idaho has adopted. Confirm requirements with the department issuing your permit. We are builders, not occupational therapists or accessibility consultants, and the right dimensions for a specific person should come from someone who has assessed that person's needs.
Frequently asked questions
Does my new home have to be accessible? No. The ADA does not cover private homes, the Fair Housing Act's construction requirements do not cover detached single-family houses, and the IRC's accessibility section engages only at four or more dwelling units. Every decision is yours.
If nothing requires it, why build it in? Because the dimensional and structural pieces are nearly free during construction and expensive or impossible afterward, and the need usually arrives on a schedule nobody chose.
What is the single most important dimension? A 60 inch turning circle in the main bathroom. The Access Board's standards give 60 inches minimum diameter, or a T-shaped space inside a 60 inch square. It is a footprint decision, so it belongs on the plan before pricing.
Can grab bars be added later? The bars, yes. The structure behind them, no. Section 609.8 requires the bar, fasteners, mounting and supporting structure to withstand 250 pounds at any point, which means blocking installed while the walls are open.
What does a zero-step entry involve? Raising the entry so finished grade meets floor level. JLC describes two methods, and the better one raises the foundation near the entry about a foot so soil never touches wood framing.
Which entrance should be the accessible one? In our view, the one from the garage, since that is the entrance a family uses through a Magic Valley winter.
Does this cost more? The footprint items do, because you are buying square footage. The blocking, door widths, outlet heights and entry-level decisions cost very little during construction. We will not quote ranges we cannot support.